Skip to content

Architectural Aluminium Solutions

Beautifully Designed

Forged by Precision

European aluminum window and door systems designed for aesthetics, performance, and lasting value.

REYNAERS AUTHORIZED FABRICATOR

Certified expertise. Trusted craftsmanship. Global standards.

CUSTOMER CENTRIC APPROACH

Every project is unique. We take a tailored approach to identify the most suitable solution for each project, carefully considering technical requirements, architectural vision, and project objectives.

ADVANCED FABRICATION

High-capacity production line with CNC machinery and certified quality. Crafted in Türkiye. Competitive Worldwide.

OPERATIONAL EXCELLENCE

We have refined every detail of our packing and loading processes to ensure that every product arrives safely, securely, and in perfect condition.

Masterwall ekibi, üretim ve proje kareleri

Taking our passion to the global stage

Since 2016, through our Consul Yapı brand we are a trusted solution partner for the aluminium systems. We have been delivering turnkey projects across Türkiye from bespoke villas to high-rise towers.

With every project, our passion has remained the same: to provide solutions that are recognized through the comfort and performance they bring to everyday life.

We founded Masterwall to take this passion beyond borders. As a 100% export-focused entity, we are deeply committed to precision manufacturing, advanced production technologies and the highest standards — delivering exceptional quality and lasting value.

Masterwall üretim tesisi

World-class products

We continuously seek new ways to raise the standards of our manufacturing. At our modern facility, equipped with advanced CNC machinery, every cutting and machining process is managed through a fully automated, barcode-driven production system.

Integrated with our ReynaPro estimation software, our entire production line operates as one seamless digital workflow. From project approval to final fabrication, every stage is precisely controlled, traceable and engineered for consistent results — minimizing human error and ensuring world-class quality in every product we deliver.

Products

Windows

Masterline 8

Window

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
0.88(Ug 0.6 · 1.23×1.48 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
E900900 Pa
Wind Load ResistanceEN 12211; EN 12210
C52000 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
46 (0;-3)44 (-2;-4)TUTI / DC
Burglar ResistanceEN 1627–1630
RC2 · RC3PAS 24

Slimline 38

Window

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
0.96(Ug 0.6 · 1.23×1.48 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
9A600 Pa
Wind Load ResistanceEN 12211; EN 12210
C41600 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
45 (-1;-5)
Burglar ResistanceEN 1627–1630
RC2PAS 24

ConceptSystem 77

Window

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
1.3(Ug 1.0 · 1.23×1.48 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
E900900 Pa
Wind Load ResistanceEN 12211; EN 12210
C52000 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
42 (-2;-4)
Burglar ResistanceEN 1627–1630
RC2 · RC3PAS 24

Doors

Masterline 8

Door

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
0.98(Ug 0.6 · 1.23×2.18 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
8A450 Pa
Wind Load ResistanceEN 12211; EN 12210
C2800 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
43 (-1;-4)
Burglar ResistanceEN 1627–1630
RC2 · RC3PAS 24

Slimline 38

Door

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
1.0(Ug 0.6 · 1.23×2.18 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
8A450 Pa
Wind Load ResistanceEN 12211; EN 12210
C31200 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
42 (-1;-3)
Burglar ResistanceEN 1627–1630
RC2PAS 24

ConceptSystem 77

Door

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
1.4(Ug 1.0 · 1.23×2.18 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
7A300 Pa
Wind Load ResistanceEN 12211; EN 12210
C2800 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
42 (-1;-4)
Burglar ResistanceEN 1627–1630
RC2 · RC3PAS 24

Sliding doors

MasterPatio

Sliding Door

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
0.8(Ug 0.6 · 4.50×2.30 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
E12001200 Pa
Wind Load ResistanceEN 12211; EN 12210
C52000 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
44 (-1;-4)
Burglar ResistanceEN 1627–1630
RC2PAS 24

Hi-Finity

Sliding Door

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
0.8(Ug 0.6 · 4.50×2.30 m · 36 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
E750750 Pa
Wind Load ResistanceEN 12211; EN 12210
C52000 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
46 (-1;-3)
Burglar ResistanceEN 1627–1630
RC2 · RC3PAS 24

ConceptPatio 130

Sliding Door

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
1.4(Ug 1.0 · 3.00×2.30 m · 24 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
E750750 Pa
Wind Load ResistanceEN 12211; EN 12210
B52000 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
39 (-1;-3)
Burglar ResistanceEN 1627–1630
RC2PAS 24

SlimPatio 68

Sliding Door

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
1.4(Ug 1.0 · 3.00×2.30 m · 24 mm glass)
Air TightnessEN 1026; EN 12207
4600 Pa
Water TightnessEN 1027; EN 12208
8A450 Pa
Wind Load ResistanceEN 12211; EN 12210
C41600 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
40 (-2;-4)
Burglar ResistanceEN 1627–1630
RC2

Curtain walls

ConceptWall 50*

Curtain Wall

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
Uf: 0.56
Air TightnessEN 1026; EN 12207
AE19501950 Pa
Water TightnessEN 1027; EN 12208
RE19501950 Pa
Wind Load ResistanceEN 12211; EN 12210
2400 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
47 (-2;-6)
Burglar ResistanceEN 1627–1630
RC2 · RC3

SlimWall 35*

Curtain Wall

Thermal Insulation Uw/UdEN ISO 10077-2 · W/m²K
Uf: 0.71
Air TightnessEN 1026; EN 12207
AE12001200 Pa
Water TightnessEN 1027; EN 12208
RE12001200 Pa
Wind Load ResistanceEN 12211; EN 12210
2000 Pa
Acoustic PerformanceEN ISO 140-3; EN ISO 717-1 · Rw (C;Ctr) dB
47 (-1;-4)
Burglar ResistanceEN 1627–1630
RC2

Uw/Ud calculated with warm edge spacer at the glazing (Ug in W/m²K), size and glass thickness shown in brackets. Performance depends on size, profile combinations, hardware and infill choices. Full datasheets available on request.

* Curtain walls: thermal value is the frame Uf (EN ISO 10077-2); classified to EN 12152 (air), EN 12154 (water) and EN 13116 (wind load).

Projects

Entrance Doors

  • Showroom DoorShowroom Door
  • Farm House DoorFarm House Door
  • GA Villa DoorGA Villa Door
  • Gokdemir Office DoorGokdemir Office Door
  • Villa DoorVilla Door
  • NRD Villa DoorNRD Villa Door
  • RG Villa 2 DoorRG Villa 2 Door
  • RG Villa 1 DoorRG Villa 1 Door
  • Villa DoorVilla Door
  • Terra Hill DoorTerra Hill Door
  • Villa DoorVilla Door
  • Showroom Pivot DoorShowroom Pivot Door
  • Showroom Pivot Door-OpenShowroom Pivot Door-Open
  • Showroom Hinged DoorShowroom Hinged Door
  • Villa DoorVilla Door

Operational Excellence

100+ International Shipments

With more than 100 international shipments successfully completed, we have refined every detail of our packing and loading processes to ensure that every product arrives safely, securely, and in perfect condition.

Optimized Loading, Maximum Efficiency

Before each shipment, every unit is carefully planned and optimized for container placement, maximizing capacity while maintaining the highest standards of protection. Partial shipments are securely packed in heat-treated wooden crates, providing additional protection throughout transit.

Secure Packaging, Reliable Delivery

From careful packing to optimized loading, every step is engineered for efficiency, reliability, and peace of mind — ensuring your products reach their destination exactly as intended.

Consultation & Estimation

CONTACT (SHOWROOM)

Beytepe Mah. Lotus Beytepe Sitesi No:27E/3

Çankaya/Ankara/TÜRKİYE

CONTACT (FACTORY)

Alcı OSB Mahallesi, 2035. Cadde No:5,

Sincan / Ankara (AS02)